Swimming Pool Air Source Heat Pump

You are here >> Swimming Pool Air Source Heat Pump

Subscribe to our e-mail list to get our FREE white paper of Heat Pumps. Keep you updated of our price list & catalogue of heat pump supply.
 

 

Swimming Pool Air Source Heat Pump

Swimming Pool Air Source Heat Pump image 1 Swimming Pool Air Source Heat Pump image 2
Swimming Pool Air Source Heat Pump image 3 Swimming Pool Air Source Heat Pump image 4
Swimming Pool Air Source Heat Pump image 5 Swimming Pool Air Source Heat Pump image 6

General features 
1. Swimming pool air source heat pump has automatic operation mode
2. It features auto-restart and auto defrosting.
3. The heat pump has friendly and intelligent LCD Control panel interface.
4. Both cooling & heating mode are optional for this heat pump.
5. The product presents wide working ambient temperature, ranging from 10 ºC to 43ºC.
6. It adopts world famous Copeland compressor.
7. Finally it includes Green refrigerant R410a/R407c for environment safety etc.
Advantages of Swimming pool air source heat pump
1. The heating capacity ranges from 7kW, 220V/1ph/50Hz to 230kW, 380V/3ph/50Hz
2. The swimming pool air source heat pump has long operating life by using the advanced stainless steel/titanium heat exchanger, which resists the erosion from chlorine in the water and creates a longer life span. 
3. It is designed for comprehensive anti-corrosion feature, in which the special case design adopts stainless steel bolts and nuts. The holes for bolts are designed to avoid the damage of the coating. Durable coating in white or stainless steel is available 
4. Special design for the fan shroud, with accurate and equal distance between the fan blades and fan shroud, offers low vibration, and low noise when running.
5. The heat pump features intelligent defrosting with revert circuit.
6. This product has cover on remote wire control panel and is waterproof
7. The refrigerant available for our swimming pool air source heat pump is R22/ R407C/ R410A.
8. Our heat pump is remarkably compact with flow switch built inside.
9. Our swimming pool air source heat pump offers safety for both water and electricity by separating insulated part without electric shock.
10. The whole units of the product are warranted for one year period.

Technical Specification of Swimming Pool Heat and Chill Pumps - Vertical style

Model

Units

HLRD
9-YC

HLRD
15-YC

HLRD
24-YC

HLRD
30-YC

HLRD
36-YC

HLRD
45-YC

HLRD
60-YC

HLRD
75-YC

HLRD
95-YC

HLRD
125-YC

HLRD
150-YC

Heating Capacity

kW

13.5

21.3

35.5

45.5

52.8

66

87.4

110

140

191

230

BTU/h

46000

73000

121000

155000

180000

225000

300000

376000

480000

650000

785000

COP

----

4.33

4.96

4.87

4.84

4.74

4.46

4.65

4.73

4.87

5.08

4.94

Cooling Capacity

kW

8.8

14.7

25.5

30.5

35.8

44.9

59.5

75

95.2

126.9

150

BTU/h

30000

50000

87000

104000

122000

153000

203000

256000

325000

430000

512000

EER

----

2.67

2.68

3.00

2.78

3.12

2.78

2.71

2.80

3.20

2.89

2.79

Max Water Outlet Temperature

45

Power Supply

V/PH/HZ

220-240V/1N~/50Hz

380V-400V/3N~ /50Hz

Rated Input Power (Heating/Cooling)

kW

3.12/
3.30

4.3/
5.50

7.30/
8.50

9.4/
11.00

11.15/
11.50

14.80/
16.20

18.80/
22.00

23.30/
26.80

28.80/
29.80

37.60/
44.00

46.60/
53.80

Rated Input Current (Heating/ Cooling)

A

14.5/
15.3

6.5/
9.9

11/
13.4

14.2/
19.8

20.1/
19.24

28.2/
30.1

33.9/
39.7

42.0/
48.3

51.92/
53.7

67.8/
79.4

84.00/
96.6

Max Input Power

kW

3.4

6.1

10

13.5

15.1

18.9

25.4

31.5

38.75

50.8

63

Max Input Current

A

15.5

9.2

15.2

20.6

27.2

34.1

45.8

56.8

69.86

91.6

113.6

Ambient Temperature

-10℃~43℃

Heat Exchanger

 

Titanium in seamless stainless steel

Refrigerant/Chare Qty

kg

R407C
/1.5

R407C
/1.9

R407C
/1.7*2

R407C
/3.8

R407C
/2.2*2

R407C
/3.5*2

R407C
/4.5*2

R407C
/5.5*2

R407C
/6.5*2

 

 

Compressor Type

 

Scroll

Number of Compressors

 

1

1

2

2

2

2

2

2

2

4

4

Number of Fans

 

1

1

2

2

2

2

2

2

2

4

4

Fan Air Flow Volume

m3/h

3900

6500

13000

13000

15600

19500

26000

32500

39000

65600

78000

Fan Direction

 

Vertical

Fan Power Input

W

180

260

320×2

320×2

550×2

550×2

640x2

1100x2

1100x2

640x4

1100x4

Fan Rotation Speed

RPM

850

850

790

790

820

820

790

820

820

790

820

Noise

dB (A)

≤54

≤56

≤61

≤61

≤66

≤66

≤66

≤68

68

71

72

Piping Diameter

mm

DN40

DN40

DN50

DN50

DN50

DN65

DN65

DN80

DN80

DN80

DN100

Discharge Pressure

Mpa

2.5

2.5

2.5

2.5

2.5

2.5

2.5

2.5

2.5

 

 

Suction Pressure

Mpa

0.3-0.8

0.3-0.8

0.3-0.8

0.3-0.8

0.3-0.8

0.3-0.8

0.3-0.8

0.3-0.8

0.3-0.8

 

 

Rated Water Pressure

Mpa

0.2~0.6

Max Water-in Pressure

Mpa

1

1

1

1

1

1

1

1

1

 

 

Min Water-in Pressure

Mpa

/

/

/

/

/

/

/

/

/

 

 

Water Flow Volume

m3/h

2.52

3.77

6.00

7.54

9.05

11.31

14.98

18.86

24.00

32.74

39.43

Net Weight

kg

90

114

214

244

276

450

472

680

720

944

1360

Shipping Weight

kg

102

128

238

268

316

487

526

734

785

1052

1468

Product Dimension

mm

695
/655
/740

703
/687
/930

1450
/705
/965

1450
/705
/1065

1450
/710
/1255

1580
/850
/1570

1990
/980
/2050

1990
/980
/2050

1900
/1020
/2050

2015
/2200
/2025

2015
/2200
/2025

Shipping Size

mm

787
/775
/842

816
/797
/1045

1535
/835
/1083

1535
/835
/1184

1560
/830
/1355

1700
/970
/1670

2110
/1100
/2150

2110
/1100
/2150

2120
/1140
/2150

2115
/2300
/2075

2115
/2300
/2075

Certificates

 

CE/CB/C-TICK/SAA

CE

 

 

Notes:

 

 

 

 

 

 

 

 

 

 

 

 

1. Heating working condition: Outdoor DB/WB temp: 24℃/19℃,62.5%RH, inlet/outlet water temp:27℃/32℃.

2. Cooling working condition: Outdoor DB/WB temp: 43℃/37℃,68%RH, inlet/outlet water temp:32℃/27℃.

3. Other sizes are available. 4. COP = heating capacity / heating power input (for heating).

 

 

 

 

 

5. EER = cooling capacity / cooling power input (for cooling).

 

 

 

 

 

6. Sizing: P= (CV (T2-T1)/t)*1.20 where P=Capacity required (kW), C=Coefficient (1.163), V=Water volume (m³), T2=Target water temp (°C), T1=Water temp before heating (°C), t=time to heat, plus add 20%.

 

Technical specification of Swimming Pool Heat and Chill Pumps- Horizontal style


Model

Units

HLRC5-YC

HLRC8-YC

HLRC9-YC

HLRC15-YC

Heating Capacity

kW

7

9.8

13.5

21.3

BTU/h

24000

33400

46000

73000

COP

----

4.83

4.76

4.33

4.96

Cooling Capacity

kW

4.5

6.2

8.8

14.7

BTU/h

15000

21000

30000

50000

EER

----

2.73

2.82

2.67

2.68

Max Water Outlet Temperature

45

Power Supply

V/ph/Hz

220-240V/1N~/50Hz

380V-400V/3N~/50Hz

Rated Input Power (Heating/Cooling)

kW

1.45/1.65

2.06/2.20

3.12/3.30

4.3/5.50

Rated Input Current (Heating/ Cooling)

A

6.6/7.5

9.6/10.2

14.5/15.3

6.5/9.9

Max Input Power

kW

1.9

2.5

3.4

6.1

Max Input Current

A

9.1

11.5

15.5

9.2

Ambient Temperature

-10℃~43℃

Heat Exchanger

 

Titanium in seamless stainless steel

Refrigerant/Charge Qty

kg

R407C/1.1

R407C/1.1

R407C/1.5

R407C/1.9

Compressor Type

 

Rotary

Scroll

Number of Compressors

 

1

1

1

1

Number of Fans

 

1

1

1

2

Fan Air Flow Volume

m3/h

2000

2600

3900

6500

Fan Direction

 

Horizontal

Fan Power Input

W

90

120

180

130x2

Fan Rotation Speed

RPM

850

850

850

850

Noise

dB (A)

≤48

≤50

≤54

≤56

Piping Diameter

mm

DN25

DN25

DN40

DN40

Discharge Pressure

Mpa

2.5

2.5

2.5

2.5

Suction Pressure

Mpa

0.3-0.8

0.3-0.8

0.3-0.8

0.3-0.8

Rated Water Pressure

MPa

0.2~0.6

Max Water-in Pressure

Mpa

1

1

1

1

Min Water-in Pressure

Mpa

/

/

/

/

Water Flow Volume

m3/h

1.20

1.68

2.31

3.65

Net Weight

Kg

38

67

97.5

114

Shipping Weight

Kg

51

85

113.5

128

Product Dimension

mm

1150/350/620

1150/350/620

1115/425/710

1110/420/1222

Shipping Dimension

mm

1200/400/670

1200/400/670

1242/540/782

1220/530/1337

Certificates

 

CE

CE/CB/C-TICK/SAA

Notes:

 

 

 

 

 

1. Heating working condition: Outdoor DB/WB temp: 24℃/19℃, 62.5%RH, inlet/outlet water temp:27℃/32℃.

2. Cooling working condition: Outdoor DB/WB temp: 43℃/37℃, 68%RH, inlet/outlet water temp: 32℃/27℃.

3. Other sizes are available.

 

 

 

 

 

4. COP = heating capacity / heating power input (for heating).

 

 

 

5. EER = cooling capacity / cooling power input (for cooling).

 

 

 

6. Sizing: P= (CV (T2-T1)/t)*1.20 where P=Capacity required (kW), C=Coefficient (1.163), V=Water volume (m³), T2=Target water temp (°C), T1=Water temp before heating (°C), t=time to heat, plus add 20%.

The swimming pool air source heat pump can be installed in many environments, including a constant temperature swimming pool, sauna constant hot water system, or for application of supplying hot water at home.
Heat pump supply is a swimming pool air source heat pump manufacturer in China. Our company provides a wide range of products including DC inverter air source heat pump, household heat pump water heater, and tube solar water heater, among others.


Swimming Pool Air Source Heat Pump May 31, 2013
Swimming Pool Air Source Heat Pump (.pdf file)
Swimming Pool Air Source Heat Pump (.doc file)

Hot Products
Latest news

Update on the



 

 

Heat Pumps Latest News Heat Pump Water Heaters Heat Pump KeywordsDownloadPricesEco-friendly Links